Detail of Frequency Band
Band 13,550 – 13,570 kHz
Notes to whole band | 5.150 |
---|---|
Part of RSUP | RSUP-P/27 |
Application Model control | |
---|---|
Section | 13,560 kHz |
Harmonisation | CEPT/ERC/DEC/(01)10 |
Authorisation | VO-R/15 |
Additional information | The stations of remote model control may use the frequency 13.56 MHz in accordance with CEPT Decision. |
Service Fixed | |
---|---|
Category of assignment | Primary |
Non-civil utilisation | Primary |
Civil utilisation | Secondary |
Note | CZ1 |
Additional information | Sharing with primary non-civil use. CZ1 applies. |
Service Mobile except aeronautical mobile (R) | |
---|---|
Category of assignment | Secondary |
Non-civil utilisation | Primary |
Civil utilisation | Not used |
Additional information | Non-civil use. |
Application Defence systems | |
---|---|
Additional information | Non-civil use on a primary basis. |
Application ISM | |
---|---|
Section | 13,553 – 13,567 kHz |
Additional information | ISM in accordance with 5.150. |
Application TTT | |
---|---|
Section | 7,300 – 23,000 kHz |
Harmonisations | CEPT/ERC/REC 70-03, 2019/1345 |
Authorisation | VO-R/10 Art. 4 |
Additional information | Radiated power -7 dBμA/m at a distance 10 m. Railway devices of EUROLOOP system. The transmission only after reception of signal from train. |
Application Active medical implants | |
---|---|
Section | 12,500 – 20,000 kHz |
Harmonisations | CEPT/ERC/REC 70-03, 2019/1345 |
Authorisation | VO-R/10 Art. 12 |
Additional information | Magnetic field strength -7 dBμA/m at a distance 10 m in bandwidth 10 kHz, duty cycle max. 10%, transmitting indoor only. |
Application RFID | |
---|---|
Section | 11,810 – 14,460 kHz |
Harmonisations | CEPT/ERC/REC 70-03, 2019/1345 |
Authorisation | VO-R/10 Art. 11 |
Additional information | For detail conditions consult General Authorisation. |
Application RFID | |
---|---|
Section | 13,553 – 13,567 kHz |
Harmonisations | CEPT/ERC/REC 70-03, 2019/1345 |
Authorisation | VO-R/10 Art. 11 |
Additional information | Magnetic field strength max 60 dBμA/m at 10m. For detail conditions consult General Authorisation. |
Application Inductive applications | |
---|---|
Section | 13,553 – 13,567 kHz |
Harmonisations | CEPT/ERC/REC 70-03, 2019/1345 |
Authorisation | VO-R/10 Art. 9 |
Additional information | Magnetic field strength max 60 dBμA/m at 10m. EAS only. For detail conditions consult General Authorisation. |
Application Non-specific SRDs | |
---|---|
Section | 13,553 – 13,567 kHz |
Harmonisations | CEPT/ERC/REC 70-03, 2019/1345 |
Authorisation | VO-R/10 Art. 3 |
Additional information | 10 mW e.r.p. For detail conditions consult General Authorisation. |
Application Inductive applications | |
---|---|
Section | 13,553 – 13,567 kHz |
Harmonisations | CEPT/ERC/REC 70-03, 2019/1345 |
Authorisation | VO-R/10 Art. 9 |
Additional information | Magnetic field strength max 42 dBμA/m at 10m. For detail conditions consult General Authorisation. |
Application Inductive applications | |
---|---|
Section | 5,000 – 30,000 kHz |
Harmonisations | CEPT/ERC/REC 70-03, 2019/1345 |
Authorisation | VO-R/10 Art. 9 |
Additional information | Magnetic field strength max -20 dBμA/m at 10m. For detail conditions consult General Authorisation. |
Non-civil Utilisation – Priority
Band reserved for non-civil utilisation. If civil utilisation is also stated with priority, the band is being used equally with civil utilisation on the basis of coordination.
Non-civil Utilisation – Subsidiarity
Non-civil stations can use the band with subsidiarity to civil ones (which use the band with priority), but must not interfere and do not have rihgt to protection against interference by civil utilisation.
Non-civil Utilisation – Not Used
Non-civil stations cannot use the band.
Civil Utilisation – Priority
Band reserved for civil utilisation. If non-civil utilisation is also stated with priority, the band is being used equally with non-civil utilisation on the basis of coordination.
Civil Utilisation – Subsidiarity
Civil stations can use the band with subsidiarity to non-civil ones (which use the band with priority), but must not interfere and do not have rihgt to protection against interference by non-civil utilisation.
Civil Utilisation – Not Used
Civil stations cannot use the band.
Note 5.150
The following bands:
13 553 – 13 567 kHz (centre frequency 13 560 kHz),
26 957 – 27 283 kHz (centre frequency 27 120 kHz),
40.66 – 40.70 MHz (centre frequency 40.68 MHz),
902 – 928 MHz in Region 2 (centre frequency 915 MHz),
2 400 – 2 500 MHz (centre frequency 2 450 MHz),
5 725 – 5 875 MHz (centre frequency 5 800 MHz), and
24 – 24.25 GHz (centre frequency 24.125 GHz)
are also designated for industrial, scientific and medical (ISM) applications. Radiocommunication services operating within these bands must accept harmful interference which may be caused by these applications. ISM equipment operating in these bands is subject to the provisions of No. 15.13 of RR.
Note CZ1
On the frequencies of fixed and land mobile services notified with Radiocommunication Bureau of ITU, the primary user is that one for which frequencies have been recorded at Radiocommunication Bureau of ITU and are noted at the Czech Telecommunication Office.